news
Trending
From View to Structure

Choosing Glass in Mazandaran’s Humid Climate Is an Engineering Decision

Key points
  • Glass selection must be based on humidity, solar radiation, wind pressure, heat transfer, acoustics, safety, installation system, and processing quality.
  • In Mazandaran's humid climate, humidity, rainfall, solar radiation, coastal wind, and altitude difference between production and installation sites are key parameters for glass selection.
  • Using High Performance glass in a case study reduced the design cooling load by about 30%.
  • Comparing glass only by price per square meter can mislead decisions; operating costs and durability must also be considered.

According to SAMA, Armin Moslehi, a specialist in architectural glass from Venus Glass Company, in his technical presentation at the 24th National Conference and Exhibition of Builders, Developers, and Designers, emphasized that as the share of glass in facades increases, its selection must go beyond the “product name” and be based on humidity, solar radiation, wind pressure, heat transfer, acoustics, safety, installation system, and processing quality.

Moslehi began his remarks by highlighting the changing role of glass in contemporary architecture, noting that the window has evolved from a small opening in the wall to a surface as large as the wall itself. In coastal projects, hotels, and buildings with views of forest and sea, it is natural for the architect to want to turn the landscape from a “frame” into part of the property’s value; however, increasing the glass surface also increases its engineering responsibility.

He explained that a wall naturally performs part of the thermal, acoustic, and solar control, and when glass replaces it, these same functions must be provided through the correct selection of glass structure and facade system. In Moslehi’s view, terms such as double-glazed, laminated, tempered, or Low-E are only the starting point of the conversation and are not sufficient for a professional choice.

Humid Climate and Parameters Affecting Glass Selection

Moslehi classified Mazandaran as a temperate and humid climate and stated that humidity, rainfall, solar radiation, coastal wind, and the altitude difference between the production site and the installation site are among the important parameters for glass selection in this province. He stressed that each of these factors can affect the durability, clarity, thermal performance, and safety of the glass unit.

On the topic of humidity and rain, he emphasized the quality of edge sealing, the type of adhesive, the presence of desiccant in the spacer, and the compatibility of all materials used in the construction of the double-glazed unit. According to him, the facade installation system must also have proper drainage; because even high-quality glass in a facade system lacking correct sealing and water drainage details will not have the expected durability.

Regarding solar radiation, Moslehi said that with the increase in glass surface, in addition to light, solar energy also enters the building, and a balance must be struck between natural light and thermal load. He proposed three main indicators for evaluating performance: visible light transmittance, solar heat gain coefficient (SHGC), and U-Value (thermal transmittance). In addition, the window-to-wall ratio (WWR) is also important in energy calculations.

He added that in facades with a high glass surface, the use of High Performance glass becomes more important; because these products can allow light to pass through while controlling a greater portion of thermal waves. Moslehi referred to the concept of Selectivity as a criterion for measuring the ratio of desirable light to unwanted energy.

Structure of the Double-Glazed Unit and Technical Requirements

He also explained the structure of a professional double-glazed unit: the outer glass with an appropriate coating, the intermediate space with argon gas, a standard or Warm Edge spacer, primary and secondary sealants, desiccant material, and the inner glass, which can be single or laminated depending on the need. According to him, the choice of each component must be aligned with the expected performance of the project.

Moslehi also pointed out the importance of “measurability” of specifications and said that the data used by mechanical engineers must be verifiable through software and technical information. This issue has become even more important with the tightening of requirements in Section 19 of the Iranian National Building Regulations.

He then addressed the issue of pressure and altitude difference. According to Moslehi, a double-glazed unit is sealed at the factory with a volume of gas, and if the altitude difference between the production and installation sites is large, the change in atmospheric pressure can make the glass convex or concave and put pressure on the edge seal. The solution is to perform proper Air Balance and design according to the project’s altitude.

In the area of coastal wind, Moslehi stressed that glass thickness, dimensions, type of lamination, and even the depth and method of glazing must be calculated based on wind load. Wind on a facade is not a constant load; it has a fluctuating and cyclic behavior; therefore, the connection system and adhesives must have sufficient durability against fatigue.

Effect of Glass Selection on HVAC Systems and Costs

To demonstrate the effect of glass selection on HVAC systems, he presented a case study of a project in Tehran. According to the figures presented, the use of High Performance glass resulted in a significant reduction in Solar Heat Gain and subsequently a reduction of about 30% in the design cooling load. Moslehi said this reduction means the possibility of choosing smaller cooling equipment, lower initial capital, and lower operating costs in subsequent years.

He emphasized that comparing glass only based on “price per square meter” can distort the decision. A high-performance glass may have a higher initial price, but if the reduction in chiller capacity, electricity consumption, glare, operating costs, and increased durability are included in the calculation, the economic picture will be different.

In another part of his speech, Moslehi addressed processing quality and said that the larger the glass dimensions and the greater its share in the facade, the more visible the visual distortion caused by tempering, edge quality, installation quality, and the torque of the connections become. Therefore, factory and installation quality control must be considered simultaneously.

In conclusion, he proposed a decision-making matrix: What climate is the project in? What is its use? How much light and view does the architect want? What is the functional goal? How is the glass structure defined and what are the specifications of the installation system? According to him, it is the simultaneous answer to these questions that turns glass selection from a product purchase into an engineering decision.

Related Articles

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button